Part Number Hot Search : 
MB95400 R1660CT URAM2H13 TR3D336 R1660CT N4003 K2148 RA152
Product Description
Full Text Search
 

To Download XE900SL10 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 XE900SL10
June 2005
XE900SL10 Miniature Spread Spectrum Transceiver
Description The XE900SL10 breaks new ground in Smart Transceiver Technology. It is a 900 MHz, Spread Spectrum Transceiver with integral micro-controller, just 1 inch square. This miniature size combined with low power consumption make the XE900SL10 perfect for mobile and battery powered applications. Xecom did not drop features to reduce size. The XE900SL10 still supports Xecom's Count-OffTM feature enabling a scan of up to 125 remote nodes in under 10 seconds. SensorOnAirTM allows sensors and control lines to utilize the embedded communications controller in place of a host micro-controller . Xecom also offers a high power spread spectrum model, the XE900S-500, for applications that require greater range. The XE900S-500 has an obstructed range of up to 1000 feet in a larger but still small package. The XE900SL10 transmits at up to 10 milliwatts with a receive sensitivity of -100 dBm to provide an obstructed range of 300 feet. All from a 1 inch square transceiver consuming less than .2W of power. Features * Small Size: 1.0" by 1.0" by 0.26" * Serial Control and Configuration of the Wireless Link. * Supports a 254 node point-to-multipoint network * Output Power Programmable from 0 to 10 mW; * Maximum Receiver Sensitivity -100 dBm * Obstructed signal range to 300 feet; * Wireless Data Rate 76.8K bps, half-duplex; * Power Consumption: 55 mA @ 3.3 Volts when transmitting at 10 mW less than 1 mA in Sleep Mode or Power-Down modes * SensorOnAirTM allows direct connection of sensors to the Smart Transceiver * Count-OffTM allows the master node to download the status of all nodes in under 10 seconds. * Operating Temperature Range of -40 to +85 C * FCC Part 15 Registered
XE900SL10 Block Diagram
Antenna
ROM
COMMUNICATIONS CONTROLLER
SAW FILTER
MUX
UHF TRANSCEIVER
Serial I/F Analog Inputs Digital I/O
XECOM
(1)
XE900SL10
XE900SL10 MECHANICAL SPECIFICATIONS
Top View
G
H
E
F
J
A
K
B C D
Dimension A B C D E F G H J K
Description Module Width Max. Module Thickness Row to Row Minimum Lead Length Module Length Pin 10 to Pin 14 Pin 14 to Edge Pin 1 to Pin 9 Pin to Pin Spacing Pin 1, 9, or 10 to Edge
Inches 1.00 0.30 1.00 0.125 1.00 0.40 0.50 0.80 0.10 0.10
MM 25.40 7.62 25.40 3.18 25.40 10.16 12.70 20.32 2.54 2.54
XECOM
(2)
XE900SL10
Layout PCB for Both XE900S-500 and XE900SL10
Despite the fact that the XE900S-500 is substantially larger module than the XE900SL10, a common PCB layout can be used to support both products. This makes it easy to accommodate applications which include nodes with both long range and short range requirements. The XE900S-500 and XE900SL10 can share board layout because of common pin assignments. Pins 1 through 8 of the XE900SL10 are equivalent to Pins 3 through 10 on the XE900S-500; they have the same functions and are placed in the same sequence. Pin 9 on the XE900SL10 is an unused pin and therefore does not conflict with the ADC1 signal assigned to Pin 11 of the XE900S-500. The XE900SL10 requires a separate pin row for Pins 10 through 14. These pins will be hidden under the XE900S500 module when the larger module is installed. The XE900SL10 also includes one unique signal, Reset. Reset is an active high signal that can be left unconnected if no external reset is desired. The figure below shows the overlapping layout that supports both modules. The XE900S-500 outline and pins are shown in green. XE900SL10 pins and outline are shown in red.
XE900S-500/XE900SL10 Overlay
Gnd Vcc /TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 ADC1/NC ADC0
1 2 3/1 4/2 5/3 6/4 7/5 8/6 9/7 10/8 11/9 12
XE900S-500 XE900SL10
14 13 12 11 10
Reset ADC0 ADC1 Vcc Gnd
XECOM
(3)
XE900SL10
Using the XE900SL10 Power Saving Modes
The XE900SL10 includes three low power operating modes (RF Monitor, Sleep and Power-Down Modes) to allow the host application to make maximum use of the available power. The #P command determines how the transceiver will operate when not being asked to transmit or receive an RF signal. Below are descriptions of all of the XE900SL10 operating modes. IDLE: In Idle Mode all circuits within the XE900SL10 are powered and available for immediate action. This includes the RF receiver which actively monitors the air for an incoming communications request. Current draw in Idle Mode is typically 18 milliamps. SLEEP: In Sleep Mode all circuits within the XE900SL10 are powered-down to reduce consumption. The XE900SL10 will not accept commands or respond to incoming RF communications requests. Any input on the TXD line will wake the transceiver and return it either the Idle or Power-Down Mode which ever mode it was last in before being put into Sleep Mode. Current draw in Sleep Mode is less than 40 microamps. Power-Down: In Power-Down Mode all RF circuitry is shut down but the communications controller remains active to accept AT commands. In this mode the XE900SL10 cannot respond to incoming RF communications requests. If a Transmit RF or Receive RF command is received, the XE900SL10 can activate the RF section in under 200 microseconds. Current draw in Power-Down Mode is less than 500 microamps. RF Monitor Mode: The XE900SL10 RF monitor mode has 4 settings. At each of these settings the transceiver sits in power down mode for a prescribed period of time. The transceiver then wakes up, turns on its receiver and checks for incoming messages. If no messages are received the transceiver returns to power down mode after about 200 milliseconds. If a carrier is detected, the transceiver completes the transaction before returning to power down mode. Intervals of 2 seconds (#P3), 4 seconds (#P4), 8 seconds (#P5) and 16 seconds (#P6) can be chosen. RF Receive Mode: In RF Receive Mode the XE900SL10 is actively receiving an incoming 900 MHz data signal. Current draw in RF Receive Mode is less than 30 milliamps. RF Transmit Mode: In RF Transmit Mode the XE900SL10 is actively transmitting a 900 MHz data signal. Current draw in Transmit mode is no more than 55 milliamps with the transmit output power set to maximum, 10 milliwatts. AT Command Control The low power modes are controlled by the AT#Pn command, see below. AT#P0 - Sets the transceiver to Idle mode. AT#P1 - Sets the transceiver to Sleep Mode. AT#P2 - Sets the transceiver for Power-Down Mode. AT#P3 - RF Monitor Mode (2 second interval) AT#P4 - RF Monitor Mode (4 second interval) AT#P5 - RF Monitor Mode (8 second interval) AT#P6 - RF Monitor Mode (16 second interval)
XECOM
(4)
XE900SL10
XE900SL10 PIN CONFIGURATION
/TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 N/C
1 2 3 4 5 6 7 8 9
Antenna
XE900SL10 Top View
14 13 12 11 10 Reset ADC0 ADC1 VCC GND
SIGNAL
/TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 N/C GND VCC ADC1
PINS
1 2 3 4 5 6 7 8 9 10 11 12
DESCRIPTION
Transmit Data is the data input to the XE900SL10. Received Data is the data output from the XE900SL10. Clear to Send provides hardware flow control from the XE900SL10. The XE900SL10 drives /CTS high to signal the host to temporarily stop the flow of data into /TXD. Request to Send provides hardware flow control from the host system. The host system drives /RTS high to signal the XE900SL10 to temporarily stop the data flow onto /RXD. DIO3 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900SL10. DIO2 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900SL10. DIO1 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900SL10. DIO0 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900SL10. No Connection Common voltage reference for the XE900SL10. 3.3 Volt power for the XE900SL10. Analog Input 1 to the XE900SL10's communications controller. ADC1 connects to an internal 12-bit Analog to Digital Convertor. ADC1 may also be configured as a digital input if no analog inputs are required. Analog Input 0 to the XE900SL10's communications controller. ADC0 connects to an internal 12-bit Analog to Digital Convertor. ADC0 may also be configured as a digital input if no analog inputs are required. Provides an active high hardware reset to the XE900SL10.
ADC0
13
Reset
14
XECOM
(5)
XE900SL10
ABSOLUTE MAXIMUM RATINGS
VCC Storage Temperature Operating Temperature Range 3.9 Volts -55O C to +125O C -40O C to +85O C
WARNING: Exceeding any of these ratings will void the warranty and may damage the device
XE900SL10 ELECTRICAL SPECIFICATIONS
Parameter
VCC ICC
Min
2.7
Typ
3.3 55 30 23 1.7 0.85 0.43 0.22
Max
3.6
Units
Volts mA mA mA mA mA mA mA
Comments
Transceiver power Transmit Mode (10 mW output) Receive Mode Idle Mode Avg; 2-sec RF Monitor interval Avg; 4-sec RF Monitor interval Avg; 8-sec RF Monitor interval Avg; 16-sec RF Monitor interval mA Idle Mode mA Power-Down Mode mA Sleep Mode mW 50 Ohm Load
18 0.500 0.040 Output Power: Wireless Receive Sensitivity Frequency Hopping Channels Frequency Range Communications Range Antenna Output Impedance Voh V ol Vih Vil 2.25 0.75 2.25 0.75 902 300 50 1 -100 50 928 MHz ft. Ohms Volts Volts Volts Volts 10 dBm
VCC =3.3 Volts VCC =3.3 Volts VCC =3.3 Volts VCC =3.3 Volts
XECOM
(6)
XE900SL10
XE900SL10 TYPICAL CONNECTION DIAGRAM
Antenna
Host Serial I/F
/TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 N/C
Reset ADC0 ADC1 VCC GND C1 C2 C3
L1
C4
C5
Parts List for XE900SL10 Typical Connection Diagram
Reference Designation C1 C2, C4 C3, C5 L1 Antenna * Qty 1 2 2 1 1 Description Capacitor, Electrolytic, 100 ufd, 10 Volts Capacitor 0.1 ufd, 10 Volts Capacitor 47 pfd, 10 Volts Coilcraft 0603HC-7N5XJB 50 Ohm, 1/4 Wave
* The Antenna connector on the XE900SL10 is a Male AMC connector. An Female AMC to Female SMA adapter is needed for the antenna connection
XECOM
(7)
XE900SL10
XE900SL10 COMMUNICATIONS CONTROLLER
The XE900SL10 uses an internal micro-controller to control communications. This micro-controller manages the interface to the host system, determines when the communications link is available, and formats data for the RF communications. HOST INTERFACE There are two primary interfaces between the XE900SL10 and the system host; the serial interface and the direct sensor interface supported by the SensorOnAirTM feature. Management of both interfaces is the responsibility of the communications controller. Serial Interface A 4-signal serial interface links the host to the XE900SL10. For most applications the XE900SL10 acts as a DCE. Control and configuration of the XE900SL10 takes place through the serial interface using modem-like AT commands. Serial data rates from 1200 bits per second to 115.2K bits per second are supported. The serial interface signals are listed below. /TXD - Transmit Data; the input to the XE900SL10 for AT commands and Data to be transmitted on the wireless network. /RXD - Received Data; the output from the XE900SL10 for received RF data and responses to AT commands. /RTS - Request to Send, provides the hardware flow control input to the XE900SL10. The DTE deactivates /RTS to stop the XE900SL10 from sending more data on the RXD line. /CTS - Clear to Send, is the hardware flow control output from the XE900SL10. The XE900SL10 deactivates /CTS to advise the host to stop inputting data on the TXD lead. XE900SL10 AT Command Format AT commands issued to the XE900SL10 follow a strict format. Each command begins with the prefix AT and ends with a carriage return. The XE900SL10 communications controller accepts commands at data rates from 1200 to 115,200 bps. The default serial data rate is 9600 bps and can be changed using register S23. The communications controller uses the AT command prefix to automatically determine the parity of the incoming characters. Command Prefix - Each command, except the A/ command, begins with the AT prefix. The "A" and "T" may be either both upper case or both lower case but cannot be of different cases. The prefix identifies parity of the commands sent to the XE900SL10 by comparing the parity bits of the "A" and the "T" characters. Command Line - Commands may be strung together in a single command line of up to 30 characters. Commands in the command string are executed in the sequence they appear. Omitted Parameters - Most commands include a parameter which determines the function setting. When the command parameter is omitted from the command string, it is assumed to be a 0. Result Codes - A result code is normally issued after each action. Result codes may be provided as full words, one or two digit numeric codes, or may be disabled all together. Each result code ends with a carriage return when numeric result codes are chosen. When full word result codes are chosen, a Line Feed and Carriage Return precede and follow each result code. Disconnect Sequence - A three character sequence initiates a disconnect of the wireless link. The sequence "~~~" is assigned to disconnect the link. DIRECT CONNECTION OF SENSORS: SensorOnAirTM Sensors can be connected directly to the XE900SL10 without requiring an applications controller. In this SensorOnAir TM configuration the XE900SL10 communications controller controls the operation of the sensors. Sensor I/O Lines SensorOnAir controls the operation of 6 I/O lines to the XE900SL10. This includes 2 analog inputs, ADC0 and ADC1, and 4 digital I/O lines, DIO0, DIO1, DIO2, and DIO3. ADC0 and ADC1 are connected to a 12-bit analog to digital converter and using a 2.5 volt reference derived from VCC as their reference voltage. The digital I/O lines can be programmed to act as either inputs or outputs.
XECOM
(8)
XE900SL10
XE900SL10 COMMUNICATIONS CONTROLLER
Configuring the XE900SL10 for Sensor Operation All SensorOnAir control functions for the analog inputs and digital I/O's are performed by the communications controller within the XE900SL10. Modem-like AT commands loaded through the serial interface, program the functions of the analog and digital I/O lines. The AT commands used to program the SensorOnAir functions are then stored in the XE900SL10's Flash memory. This allows the XE900SL10 to be first programmed and then installed in the application. The communications controller uses the information stored in Flash memory to control the analog and digital I/O lines. SensorOnAir CommandsTM Below is a list of the AT commands used to program the direct control of sensors using the communications controller in the XE900SL10.
S107 Defines the function of the programmable I/O lines. The two analog input lines, ADC0 and ADC1, can also be defined as digital I/O lines if needed. The four programmable digital I/O lines, DIO0, DIO1, DIO2, and DIO3; can be set as either inputs or outputs. The value of this command is stored in flash memory within the XE900SL10.
WIRELESS COMMUNICATIONS The communications controller manges the RF Link. This includes the frequency hopping algorithm for spread spectrum operation; collision avoidance, node addressing, and packetizing data. The communications controller allows support for point-to-point, point-tomultipoint or multipoint networks. Carrier Sense Multiple Access (CSMA) To prevent collisions between network nodes the XE900SL10 uses a Carrier Sense Multiple Access protocol for each network transceiver. In normal communications all nodes, including the Master node in a point-to-multipoint network, listen for communications activity before initiating a session. If a wireless link already exists, the transceiver waits until that session is complete before initiating a wireless link. Data Packets All data presented by the system host is placed into packets by the XE900SL10 communications controller for transmission across the wireless link. These packets provide addressing and error correction for the wireless communications. The communications controller places the data in packets only for the wireless link. The data is extracted from the packets before being sent out the serial interface. File Transfer Mode Xecom's XE900SL10 incorporates a File Transfer mode that uses a simplified networking protocol so that the maximum data transfer rate is achieved. In this mode the XE900SL10 does not automatically retransmit blocks containing errors. A CRC 16 checksum is calculated, transferred at the end of the file, and checked by the receiving unit. An "ERROR" message is displayed if the checksum calculated at the receive end does not match the checksum transmitted with the data. The File Transfer Mode is controlled by the AT#T command. The format of the command is AT#Txx; where xx is the destination address of the file. Following is a sample file transfer.
AT&IAn? - This command allows a local host to read the value of Analog Input "n." AT&IDn? - This command allows a local host to read the status of Digital I/O "n." AT&IDn=z - This command allows a local host equipment to set the condition of the local digital output "n." When z=0 the output is set to a logic low; when z=1 the output is set to a logic high. AT#IxxxAn? - This command allows the value of Analog Input "n" on node address "xxx" to be read remotely. AT#IxxxDn? - This command allows the status of Digital I/O "n" on node address "xxx" to be read remotely AT#IxxxDn=z - This command allows the condition of the local digital output "n" on node address "xxx" to be set remotely. When z=0 the output is set to a logic low; when z=1 the output is set to a logic high.
XECOM
(9)
XE900SL10
XE900SL10 COMMUNICATIONS CONTROLLER
Sample File Transfer
Transmitter TXD AT#T01 abc...z 3 sec pause in data RXD : Receiver TXD RXD FILE abc...z A718 OK or ERROR Description Initiate File Transfer Link Established File Data Checksum at End of File Transfer File Transfer Successful Error Detected in File Transfer
Notes: The above example shows that the file transfer is assumed to be completed if three seconds pass with no data being presented to the TXD input on the serial port. File Transfer Mode cannot be used to send binary data. Multipoint Network System designers using the XE900SL10 can create a point-to-multipoint network with up to 125 remote nodes. The master node is assigned address 1. The remote nodes are assigned address from 2 to 126. Xecom created Count-Off to insure efficient network operation. Count-Off allows the master node to poll the entire network in less than 10 seconds. The Count-Off creates a temporary time division multiplexing scheme which permits each node to report its status without the handshaking sequence normally required for a wireless data exchange. The Count-Off sequence is initiated by the AT#C command from the host system. The Master node broadcasts the Count-Off command to all network nodes. Upon receipt of the Count-Off broadcast each remote node initializes an internal timer. Then in sequence by address each node sends an 8-byte status message to the Master. The status message is programmed with the AT#E: or AT#E= command. Due to difficulties in synchronizing the spread spectrum signals, a node may sometimes miss the Count-Off command. The network administrator should poll any node that does not respond to the Count-Off request to insure the network integrity Using Count-Off network reporting will be completed in less than 10 seconds. Based on the status information the host can then elect to service any of the remote nodes.
COUNT-OFF SEQUENCE
Node 1 Node n Node 2 Node n Node 1 Node 2 Node n Node 1 Node 2 Node n Node 1 Node 2
Node 9 Master Node 8
Node 3
Node 9 Master
Node 3
Node 9 Master
Node 3
Node 9 Master
Node 3
Node 4
Node 8
Node 4
Node 8
Node 4
Node 8
Node 4
Node 7 Node 6
Node 5
Node 7 Node 6
Node 5
Node 7 Node 6
Node 5
Node 7 Node 6
Node 5
T0 - Master Broadcasts Count-Off Initiation
T1 - Node 1 Transmits 8-Byte Status
T2 - Node 2 Transmits 8-Byte Status
Tn - Node n Transmits 8-Byte Status Count-Off Complete
XECOM
(10)
XE900SL10
AT COMMANDS
An asterisk indicates the factory default A Dn En Answer Command - forces the smart transceiver respond to a summons from another wireless device. Initiate a Wireless Link - attempts to establish a connection with the transceiver at address n. Echo Characters - determines if the XE900SL10 will echo the characters received on its serial interface during command mode. n=0 Characters not Echoed n=1 Characters Echoed * In Identification - displays product identification code. n=0 Display Product Code n=1 Display Product Name n=2 Display Model Number n=3 Display Copyright n=4 Display Firmware Revision Qn Result Code Display - determines if result codes will be displayed. n=0 Display Result Codes * n=1 Do not Display Result Codes Sn= Set Value of Register Sn Sn? Vn Read Value of Register Sn Response Type - selects Full Word or Numeric responses n=0 Numeric Responses n=1 Full Word Responses * Zn Reset - executes a soft Reset n=0 Reset to Values Stored in User Profile 0 *. n=1 Reset to Values Stored in User Profile 1 &F Restore Factory Settings - returns all configuration commands and registers to their factory default values. #B #C &V &IDn? Read Local Digital Input "n" - This command allows the host equipment to read the status of the local digital inputs. n=0 Read input DIO0 n=1 Read input DIO1 n=2 Read input DIO2 n=3 Read input DIO3 n=4 Read input DIO4 (pin shared with ADC0) n=5 Read input DIO5 (pin shared with ADC1) &IDn=z Set Local Digital Output "n" - This command allows the host equipment to set the condition of the local digital outputs. When z=0 the output is set to a logic low; when z=1 the output is set to a logic high. n=0 Set output DIO0 n=1 Set output DIO1 n=2 Set output DIO2 n=3 Set output DIO3 &Kn Flow Control - selects the type of flow control to be used between the system host and the XE900SL10 n=0 Flow Control Disabled n=3 RTS/CTS, hardware Flow Control n=4 XON/XOFF, in-band Flow Control View Active Configuration - sends the active configuration data to the system host.
&Wn Store Current Configuration - loads the current XE900SL10 configuration into either User Profile 0 or User Profile 1. n=0 load configuration into User Profile 0 n=1 load configuration into User Profile 1 Wireless Broadcast Mode - initiates wireless broadcast mode for diagnostic purposes. Count-Off Request (ASCII) - Initiates a "count-off' sequence in the network with node status to be reported in ASCII format. Count-Off Response (ASCII) - Programs the nodes 8 byte response to a "count-off' request from the network hub in ASCII format. Count-Off Response (Hex) - Programs the nodes 8 byte response to a "count-off' request from the network hub in hexadecimal format.
&IAn? Read Local Analog Input "n" - This command allows the host equipment to read the values of the local analog inputs. n=0 Read input ADC0 n=1 Read input ADC1
#E:
#E=
XECOM
(11)
XE900SL10
AT COMMANDS
#IxxxAn? Read Analog Input "n" at Node Address xxx This command allows analog input values at any node to be read remotely. n=0 Read input ADC0 n=1 Read input ADC1 #IxxxDn? Read Digital Input "n" at Node Address xxx This command allows the status of the digital inputs at any node to be read remotely. n=0 Read input DIO0 n=1 Read input DIO1 n=2 Read input DIO2 n=3 Read input DIO3 n=4 Read input DIO4 (pin shared with ADC0) n=5 Read input DIO5 (pin shared with ADC1) #R #Pn Low Power Operation - Allows the XE900SL10 to operate in reduced power modes. n=0 Selects Normal Power Mode n=1 Places Transceiver in Sleep Mode; n=2 Places Transceiver in Power-Down Mode Receive Broadcast - Allows the XE900SL10 to receive a broadcasted message and present it on the serial interface #IxxxDn=z Set Digital Output "n" at Node Address xxx This command allows the condition of the digital outputs to be modified remotely. When z=0 the output is set to a logic low; when z=1 the output is set to a logic high. n=0 Set output DIO0 n=1 Set output DIO1 n=2 Set output DIO2 n=3 Set output DIO3
#Txx File Transfer - initiates a file transfer to the destination address xx.
XE900SL10 Responses
Numeric 0 1 2 3 4 6 7 8 9 Full Word OK CONNECT RF RING DISCONNECT ERROR NO CONNECTION BUSY SORRY WAIT FILE Description Successfully executed command line Wireless Connection Established Wireless Link Request Detected Lost Wireless Link Error in command line Failed to Establish Wireless Link Link Request Time Out has occurred No Response to Count-Off Request Wireless Link is not available File Transfer Mode
XECOM
(12)
XE900SL10
XE900SL10 Configuration Registers
S0 Answer Wireless Link Request: S0 determines if the XE900SL10 will automatically respond to a wireless link request. S0=0 S0=1 No Automatic response to link requests Automatically respond to link requests S14 Bit-mapped Register - S14 stores the values of the ATE, ATQ and ATV commands. S23 Serial Interface Data rate - Set the serial data rate. Range 1-10 1 = Set serial data rate to 1200 BPS 2 = Set serial data rate to 2400 BPS 3 = Set serial data rate to 4800 BPS 4 = Set serial data rate to 9600 BPS* 5 = Set serial data rate to 14400 BPS 6 = Set serial data rate to 19200 BPS 7 = Set serial data rate to 28800 BPS 8 = Set serial data rate to 38400 BPS 9 = Set serial data rate to 57600 BPS 10 = Set serial data rate to 115200 BPS S39 Bit-mapped Register - S39 stores the value of the AT&K command. S104 Group ID Number - S104 sets the Group ID number. Multiple groups may be active in the same area. Only devices with the same group ID can communicate. Range: 0-255
S0=128 Automatically enter Broadcast mode on power-up. Command must be stored in nonvolatile memory using the AT&W command. S2 Wireless Disconnect Character - S2 sets the ASCII character to be used in the link disconnect sequence. The default character is the tilde "~". Range: 0-255
Default: 126 S7 Link Set-up Timer - S7 sets the length of time in seconds that the transceiver will attempt to create a link with the destination node. Range: Default: 0-60 10
S10 Link Recovery Timer - S10 sets the length of time in seconds that the transceiver tries to recover a broken link. Range: Default: 0-60 10
Default: 1 S105 XE900SL10 ID Number - S105 sets the node ID. Each unit on the Network must have a unique ID number. The ID number of the Master Node should always 1. Range: 1-254
S12 Disconnect Guard Timer - S12 sets the guard timer in milliseconds before and after the disconnect sequence. If any characters other than the disconnect sequence are received within the window defined by S12 the disconnect request will be ignored. Range: 0-255
Default: 20 Units: Milliseconds
XECOM
(13)
XE900SL10
XE900SL10 Configuration Registers
S107 I/O Configuration - S107 is a bit-mapped register which defines the local programmable I/O lines. Bit 0 = 0 - ADC0 & ADC1 used as Programmable I/O = 1 - ADC0 & ADC1 defined for Analog use Bit 1 = reserved Bit 2 = 0 - DIO0 used as an output = 1 - DIO0 used as an input Bit 3 = 0 - DIO1 used as an output = 1 - DIO1 used as an input Bit 4 = 0 - DIO2 used as an output = 1 - DIO2 used as an input Bit 5 = 0 - DIO3 used as an output = 1 - DIO3 used as an input Bit 6 = 0 - DIO4 used as an output (Bit 0 = 0) = 1 - DIO4 used as an input Bit 7 = 0 - DIO5 used as an output (Bit 0 = 0) = 1 - DIO5 used as an input Default: 193 S108 Transmit Level Control - S108 sets the transmit level of the XE900SL10. 0 = Transmit level -5 dBm 1 = Transmit level 0 dBm 2 = Transmit level 5 dBm 3 = Transmit level 10 dBm*
XECOM
(14)
XE900SL10
FCC PART 15 REGULATIONS
Mounting the XE900SL10 in Your Assembly The XE900SL10 must be mounted horizontally on your printed circuit board to maintain proper orientation of the transceiver. The XE900SL10 may not be co-located with any other antenna or transmitter. XE900SL10 Antenna The XE900SL10 is certified for compliance to FCC Part 15 rules only using the Xecom XE900A10, 1/4 wave monopole antenna. Use of any other antenna violates FCC Part 15 rules. FCC Part 15 Certification The XE900SL10 has been certified per FCC Part 15 rules for integration into OEM products without further testing or certification. This certification is your assurance that the XE900SL10 will not cause harmful interference. Labeling Requirements FCC rules require the Original Equipment Manufacturer using the XE900SL10 to place an appropriate label on the outside of the finished equipment. The label must be clearly visible and include the information shown below. Contains Transmitter Module FCC ID: DWE-XE900SL10 WARNING: This device complies with Part 15 of the FCC Rules. Its operation is subject to the following conditions: (1) This device may not cause harmful interference. (2) This device must accept any received interference including interference that may cause undesired operation. Limitations The XE900SL10 is registered under FCC Part 15 Rules. To utilize this registration on your OEM System you must follow the applications circuit provided in this data sheet and use one of the listed antennas. Any changes or modifications to the recommended circuit must be approved by Xecom. Failure to seek Xecom's approval for modifications could void certification of the end product. Warning: RF Exposure The XE900SL10 is approved for mobile, base station applications. A minimum separation of 20 centimeters should be maintained between the antenna and the equipment operator. To ensure compliance, operation at distances closer than those defined is not recommended. The Warning message below must be included in the user Manual for the end product. To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20 cm separation distance between the antenna and all persons. FCC Notifications The XE900SL10 generates radio frequency energy. It must be installed according to the manufacturer's guidelines stated in the data sheet or it has the potential to cause interference with other radio devices. Testing has been performed to assure that it conforms with the FCC Part 15 rules for intentional and unintentional radiators. No further EMI compliance testing of the transmitter is required as long as the 20 cm separation and co-location requirements are observed. Each new use of the module will, however, need to be scanned for unintentional radiation from digital clocks, etc. All necessary calibration has been performed at the time of manufacture. Any modification of the device after it leaves the factory is a violation of FCC rules.
XECOM
(15)
XE900SL10
Terms of Sale
Devices sold by XECOM are covered by the warranty provisions appearing in its Terms of Sale only. XECOM makes no warranty, express, statutory, implied, or by description regarding the information set forth herein, or regarding the freedom of the described devices from patent infringement. XECOM makes no warranty of merchantability or fitness for any purposes. XECOM reserves the right to discontinue production and change specifications and prices at any time and without notice. This product is intended for use in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment, are specifically not recommended without additional processing and authorization by XECOM for such application. Xecom assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xecom product. No other circuits, patents, or licenses are implied.
Life Support Policy
Xecom's products are not authorized for use as Critical Components in Life Support Devices or Systems. Life Support Devices or Systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided in the labeling, can be reasonably expected to result in significant injury to the user. A Critical Component is any component of a life support device or system whose failure to perform can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness.
Copyright, Xecom (c) 2005 While Xecom, Inc. has made every effort to ensure that the information presented here is accurate, Xecom will not be liable for any damages arising from errors or omission of fact. Xecom reserves the right to modify specifications and/or prices without notice. Product mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
Xecom Incorporated 374 Turquoise Street, Milpitas, CA 95035 Ph:408-942-2200 Fax:408-942-1346 E-Mail: info@xecom.com
XECOM
(16)
XE900SL10


▲Up To Search▲   

 
Price & Availability of XE900SL10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X